Skip to content
Services · Section 07 84 00

Firestop systems and passive fire compartmentation

Every penetration through a fire-rated wall or slab is a potential path for fire and smoke. We seal it with the UL/ULC listed system that matches the assembly, then document it for inspection, in Montréal and across Québec.

Firestop sealing of an opening crossed by plumbing pipes
Services

What we seal

Plumbing penetrations

Metallic and plastic pipes, insulated or not, passing through fire-rated walls and slabs.

Electrical penetrations

Cables, bundles, conduits and cable trays, including multiple penetrations.

Ventilation ducts

Mechanical ducts and shafts, around dampers and sleeves.

Firestop joints

Head-of-wall, wall-to-slab, perimeter edge-of-slab and expansion joints in fire separations.

Openings and blockouts

Open penetrations, planned sleeves and openings left for future services.

Code compliance upgrades

Deficiency surveys and correction of penetrations in existing buildings.

Code compliant, ready for inspection

In Québec, the Construction Code requires that gaps around services passing through a fire separation be sealed with a firestop system tested to CAN/ULC-S115.

We install listed systems only, with the required rating (F or FT). When no listed system matches the configuration, we obtain an engineering judgment from the manufacturer.

  • A Hilti Accredited Firestop Specialty Contractor since 2025.
  • FCIA member since 2020.
  • Installers trained in the Hilti and 3M manufacturer programs.
  • When required, a photo report with labelling of penetrations.
Our firestop method

From survey to delivery.

  1. 01

    Survey

    Survey of penetrations and joints.

  2. 02

    Analysis

    Analysis of issues on the drawings, from the design stage.

  3. 03

    Selection

    Selection of listed systems and engineering judgments.

  4. 04

    Installation

    By our installers, accredited by the manufacturers.

  5. 05

    Report

    When required, a photo report with labelling of penetrations.

Projects

Completed projects

See more projects →
CHUM – Phase 2 in Montréal
Healthcare

CHUM – Phase 2

Hôpital de Vaudreuil-Soulanges
Healthcare

Hôpital de Vaudreuil-Soulanges

Place Banque Nationale in Montréal
Commercial

Place Banque Nationale

Jean-R.-Marcotte wastewater treatment plant
Infrastructure

Jean-R.-Marcotte plant

Frequently asked questions

Your questions

What is a listed firestop system?

It is a precise combination of materials (sealant, foam, collar, mineral wool, etc.) tested with a given wall or floor type and a given penetrating item. Each system has a listing number and is valid only for the configuration tested.

What is an engineering judgment?

When a configuration does not match any listed system, the manufacturer’s engineer issues a technical opinion based on similar tests. This document must be accepted by the project professionals.

What is the difference between an F rating and an FT rating?

The F rating is the time during which the system prevents the passage of flames. The FT rating adds a limit on temperature rise on the unexposed side, required in certain situations.

Do you provide documentation for inspection?

Yes. When required, we provide a photo report with labelling of penetrations, which simplifies inspection and building turnover.